CD_362+FS: SIL3 / PLe absolute encoder in a 36 mm housing

TR-Electronic describes the CD_362+FS as the smallest safe absolute encoder currently on the market that meets SIL3 or PLe with Category 3. Its diameter is only 36 mm, yet it contains a redundant encoder system with two multiturn gearboxes and two sets of sensors. It also supports the safe bus protocols TR already uses in its larger encoders. Designers can now put a safety function in places where a safe encoder used to be too large.
Redundant sensing in a small housing
The encoder senses rotation on two channels. Each channel has its own gearbox and its own detection, and the power supply is monitored. Internal hardware diagnostics combine the results and pass them on in a safe transmission protocol.
- two-channel rotation sensing
- rotation detection via two gearboxes and separate detection systems
- monitored power supply
- internal hardware diagnostics, consolidated into a safe transmission protocol
Safe bus protocols without the wiring overhead
The 362 series implements the safe bus protocol in compliance with the standards and is certified for CANopen Safety and IO-Link Safety.
Protocols that normally run over Industrial Ethernet are handled differently. The encoder generates PROFIsafe, CIP Safety™, openSAFETY and FSoE securely inside its own electronics and sends them over an RS-485-based serial interface. Because the system follows the "black channel" principle, errors are detected reliably regardless of the transmission channel.
TR deliberately kept the serial interface simple: few wires, unshielded cables and a direct 5 V supply. This setup suits local controllers. Standard connection technology would take up installation space for no benefit, since it needs M12 connectors, a bus topology and a 24 V supply on separate wires. According to TR, customers can load the safety protocol directly into their own controller.
Use in AGVs
Autonomous guided vehicles (AGVs) have to monitor several steering angles. The whole steering function must meet safety requirements up to SIL 3, and there is very little installation space. AGVs usually run on rechargeable batteries, so energy has to be used efficiently.
The modular cabling of conventional fieldbuses, including safety fieldbuses, brings no advantage in such highly integrated logistics equipment. AGV control platforms work well with sensors and actuators connected point-to-point over serial interfaces. Certified protocols carried over this physical layer keep the transmission safe. PROFIsafe, for example, is fully implemented and only the type of channel changes. Users stay with established, proven protocols and avoid extra cabling.
Medical devices and the CIB2X+FS converter
Medical equipment keeps getting smaller, while its safety requirements remain strict. For this reason it usually uses type-tested sensors with a SIL classification. The compact CD_362+FS series is well suited to these devices.
When a standard interface is needed to talk to higher-level systems, the CIB2X+FS converter module converts the serial signals from up to 4 CD_362+FS encoders to a standard Ethernet interface. The converter also follows the "black channel" principle, so its response to errors does not depend on the transmission path.
CD_362+FS family: specifications
Mechanical
- encoder diameter: 36 mm
- typical overall length: 42 mm
- solid shaft or through-hole / slip-on hollow shaft versions
- blind-hole hollow shaft and slip-on hollow shaft: form fit with a keyway in the clamping ring; shaft diameters 6, 8, 10, 12, 15 mm
- solid shaft: frictional fit, optional positive fit with a key on the face; shaft diameters 6, 8, 10 mm
Interfaces (M12 connectors or cable glands)
- CANopen Safety
- IO-Link Safety
- SSI+SSI
- SSI + Incremental
Safe protocols over a serial connection
- PROFIsafe
- CIP Safety™
- OpenSAFETY
- FSoE
TR-Electronic has made absolute encoders for more than 40 years and SIL3-compliant sensors for more than 20 years.
Stoltronic distributes TR-Electronic products in Poland. We can help you choose the right CD_362+FS version (shaft, interface, safety protocol and, if needed, the CIB2X+FS converter) and prepare a quotation. Get in touch with us.